Franklin single phase motors Specifications:

  • Hermetically sealed stator
  • Lubricated bearings
  • Corrosion-resistant stainless steel AISI 304 SS
  • Fully sealed and detachable Water Bloc ™ cable connection
  • Filling the engine completely eliminates deformation at the time of start
  • High efficiency, low operating temperature
  • Environmentally friendly filling
  • All materials comply with KTW guidelines
  • from 0.25 to 2.2 kW
  • 220 V – 230 V / 50 Hz
  • 230 V – 240 V / 50 Hz
  • Torque: 1.500N; 2.500N; 4.500N
  • Requires an always-on capacitor

Additional functions:

  • VDE compliant cable
  • Built-in lightning protection
  • Built-in overload protection (0.25 – 0.75 kW)

When choosing a complete Franklin motor set with DRP protection?

When you need your pump protected from:

  • Dry run.
  • Many multiple starts and stops.
  • Engine overheating.
  • Overloads, electrical discharges.

Other Manufacturing Details:

  • Meets NEMA 4 “standard
  • Protection class: IP68
  • insulation: Cl. B , those
  • Medium temperature: max. 30 ° C
  • Minimum cooling flow: 8 cm / s
  • Maximum starts per hour: 20
  • Installation: vertical / horizontal
  • Maximum voltage fluctuations: + 6% / -10% U N
  • protection must comply with: EN 60947-4-1 (. contactor off time <10 seconds at 5 I x N )
A control panel (protection unit) is required to start and operate the H3F – optional.
A CBH control panel is required to start and operate a Franklin H3F PSC series single phase motor.
DETAILMATERIAL DIN / AISI
Shell1.4301
Top endbell, cover1.4301
Upper endbellCast iron with special covering
Lower endbellCast iron with special covering
Bottom endbell cover1.4301
Diaphragm cover1.4301
Stud1.4301
Nut1.43.01
Shaft sealLip seal BUNA N
Seal coverDelrin 500
SlingerBUNA N
Shaft end1.4305
DiaphragmBUNA N
LeadEPDM
Jam nut (lead)Brass
Lead sleeveNickel plated
Lead bushingNeoprene
Other sealsBUNA N
H3F franklin motor

Franklin single phase motors H3F – 220-230 V

50Hzn
~ 2850 min -1

Series H3F (PSC) – FRANKLIN SINGLEPHASE WATER FILLED ENGINE.
A remote control (protection unit) is required for start-up and operation.
Code
Cable (m)
Franklin code
Power
Torque
N
N
START
ƞ eff
Cos ɸ
C450v
START
IN
M
[kW]
[HP]
[N]
[min -1]
[AND]
[AND]
[%]
(Pf)
(µF)
N
[mm]
[kg]
H3F.025.15.DRP
196191105S
2
254 803 1621L
0.25
0.33
1500
2865
2.8
7.2 – 8.4
54-50
0.92
12.5
0.95 – 1.05
223
8.7
H3F.025.15
196191105L
1.5
8.2
H3F.037.15.DRP
196191110S
2
254 805 1621L
0.37
0.5
1500
2855
3.3
10.7 -11.2
56-53
0.95
sixteen
0.76 – 0.84
242.1
9.5
H3F.037.15
196191110L
1.5
nine
H3F.055.15.DRP
196191115S
2
254 807 1621L
0.55
0.75
1500
2850
4.4
15.4 – 16.1
64-63
0.96
20
0.69 – 0.76
270.8
10.8
H3F.055.15
196191115L
1.5
10.3
H3F.075.15.DRP
196191120S
2
254 808 1621L
0.75
1
1500
2850
5.8
20.2 – 21.1
61-60
0.99
thirty
0.81 – 0.89
298.5
12.2
H3F.075.15
196191120L
1.5
11.7
H3F.110.30.DRP
196191125S
2
254 809 1621L
1.1
1.5
3000
2850
7.8
30.1 – 31.5
64-62
0.96
40
0.76 – 0.84
327.2
13.7
H3F.110.30
196191125L
1.5
13
H3F.150.30.DRP
196191130S
3
254 810 1621L
1.5
2
3000
2815
10.5
33.9 – 35.4
67-66
0.97
50
0.66 – 0.73
355.9
15.2
H3F.150.30
196191130L
2.5
14.5
H3F.220.40.DRP
196191135S
3
254 811 2521L
2.2
3
4000
2825
10.5
54.2 – 56.7
65-66
0.98
70
0.59 – 0.65
460.4
19.8
H3F.220.40
196191135L
2.5
19.2

H3F – 230-240V

50Hzn
~ 2850 min -1

Series H3F (PSC) – FRANKLIN SINGLE PHASE WATER-FILLED MOTORS and cable.
A remote control (protection unit) is required for start-up and operation.
Code
Cable (m)
Franklin code
Power
Torque
N
N
START
ƞ eff
Cos ɸ
C450v
START
IN
M
[kW]
[HP]
[N]
[min -1]
[AND]
[AND]
[%]
(Pf)
(µF)
N
[mm]
[kg]
H3F.026.15.DRP
196191205S
2
254 813 1621L
0.25
0.33
1500
2865
2.8
7.2 – 8.4
54-50
0.92
12.5
0.95 – 1.05
223
8.7
H3F.026.15
196191205L
1.5
8.2
H3F.038.15.DRP
196191210S
2
254 815 1621L
0.37
0.5
1500
2855
3.3
10.7 -11.2
56-53
0.95
sixteen
0.76 – 0.84
242.1
9.5
H3F.038.15
196191210L
1.5
nine
H3F.056.15.DRP
196191215S
2
254 17 1621L
0.55
0.75
1500
2850
4.4
15.4 – 16.1
64-63
0.96
20
0.69 – 0.76
270.8
10.8
H3F.056.15
196191215L
1.5
10.3
H3F.076.15.DRP
196191220S
2
254 818 1621L
0.75
1
1500
2850
5.8
20.2 – 21.1
61-60
0.99
thirty
0.81 – 0.89
298.5
12.2
H3F.076.15
196191220L
1.5
11.7
H3F.111.30.DRP
196191225S
2
254 819 1621L
1.1
1.5
3000
2850
7.8
30.1 – 31.5
64-62
0.96
40
0.76 – 0.84
327.2
13.7
H3F.111.30
196191225L
1.5
13
H3F.151.30.DRP
196191230S
3
254 820 1621L
1.5
2
3000
2815
10.5
33.9 – 35.4
67-66
0.97
50
0.66 – 0.73
355.9
15.2
H3F.151.30
196191230L
2.5
14.5
H3F.221.40.DRP
196191235S
3
254 821 2521L
2.2
3
4000
2825
10.5
54.2 – 56.7
65-66
0.98
70
0.59 – 0.65
460.4
19.8
H3F.221.40
196191235L
2.5
19.2

Showing 1–15 of 22 results

×

 

Hello!

Click one of our contacts below to chat on WhatsApp

× Whatsapp Here